Chimney Chase Cover in Bell, Built to Drain
Describe What You See
Put the address and the symptom on the form. A technician calls back with the visit this job needs and its listed price, if it has one.
On the Burrows Checklist
Prefab fireplaces often sit inside a framed chase with a metal top. Plain steel tops rust, sag and hold water, which then runs down inside the chase and into the walls. We measure the chase, order a stainless cover with a raised collar and a slope, and fit it with a new storm collar on the flue. Chase covers in Bell are quoted in writing once the chase is measured.
How a Chase Top Rusts and Leaks
Not every chimney is brick. Many factory-built and gas fireplaces in Bell homes, especially in additions and newer construction, vent through a metal flue inside a wood-framed box on the outside of the house, finished in stucco or siding to look like a chimney. That box is the chase, and its top is a sheet of metal with a hole for the flue and a collar around it. Builders often fitted a flat galvanized top. Over years, a flat top collects rainwater in the middle, the coating wears off, and rust works through. Water then drips onto the framing inside the chase, down the metal flue and into the firebox or the wall beside it. The signs owners notice are rust streaks running down the stucco, a stain on the ceiling or wall near the fireplace, or rust inside a gas fireplace's firebox. On a direct-vent unit, water inside the chase can also reach the vent pipe joints.
The visit is on the roof. We look at the chase top for rust, holes, sagging and standing water, at the collar around the flue, at the storm collar that sheds water off the flue pipe, and at the cap above it. We also look at the edges, where the top laps over the chase sides, since a top that does not overhang lets water run behind the siding. Inside, we check the firebox and the wall near the fireplace for water, and on a gas unit we look at the vent connections we can reach. If water has been getting in for a while, the framing inside the chase may be soft, and the report says so with photos. From there we say whether the top can be resealed or should be replaced, and almost always it is the latter.
What the Chase Cover Quote Covers
Chase covers are quoted in writing after we measure, because each one is made to the size of the chase and the position of the flue. The quote lists the new cover in stainless steel, which outlasts galvanized steel by a wide margin, shaped with a slope or a raised center so water drains off, with a drip edge on all sides and a collar sized to the flue. It lists removal of the old top, the storm collar, the cap if it needs replacing, and sealing at the edges. If the framing under the old top has rotted, that repair goes on its own line. Where the leak has reached inside the house, we name the water source as closed in the note, so a drywall contractor knows the ceiling can be fixed. Leak repair more broadly runs $560 to $3,350 when the chase needs more than a new top.
Install day is short. The old top comes off, any soft framing at the top is replaced, the new cover goes on and is fastened through the sides rather than the top so no new holes face the sky, and the collar and storm collar are sealed around the flue. The cap is refitted. The gas fireplace below is relit and its draft checked, and on a direct-vent unit we confirm the vent termination is clear. You get photos of the old top, the framing and the new cover. A rusted chase top is one of the items buyers' inspectors flag, and our up-to-code repairs page explains how such fixes fit into a sale. Homes in Bell, South Gate, Montebello and Los Angeles book a chase cover visit through the contact form. A photo of the rust streaks or the top helps.
How Burrows Chimney Contractors Handles the Job
Tested First
Readings taken before any part is swapped
Maker's Parts
Listed for the model on your rating plate
Written Price
Agreed before work starts
Your Record
Readings, parts and photos left with you
Chimney Chase Cover in Your City
Each city page covers the houses, the weather and the ZIP codes we reach for this service.
No city by that name here. Try a neighboring one.
Jobs That Often Come Next
Chimney Sweep
Soot and creosote brushed out of the flue, with the cap screen, smoke shelf and damper cleared on the same visit.
Open this job →Chimney Inspection
A Level 1 or Level 2 look at flue, damper, firebox and cap, picked to match what has changed since the last visit.
Open this job →Chimney Repair
Cracked crowns, open mortar, loose brick and rusted caps repaired after the cause is found, priced line by line in writing.
Open this job →Fireplace Inspection
Firebox, hearth, mantel gap, damper and any gas parts checked against the building code or the unit's own listing label.
Open this job →Fireplace Repair
Cracked firebrick, worn refractory panels, stuck dampers and smoky openings repaired with parts and mortars rated for heat.
Open this job →Chimney Level 2 Inspection
Camera run through the full flue plus attic and crawl space checks, booked for a sale, a new appliance or after a quake.
Open this job →Chimney Cap Installation
Stainless or copper caps with spark mesh, measured to the flue and fastened so wind cannot lift them off.
Open this job →Chimney Flashing Repair
Metal at the roofline rebuilt in two overlapping layers, with a cricket behind wide stacks so water runs around them.
Open this job →Chimney Masonry Repair
Open joints repointed, crumbling brick swapped for matched units and crowns rebuilt, using mortar softer than the brick around it.
Open this job →Chimney Rebuilds
Loose or leaning stacks taken down to sound brick and built back with steel, ties and a liner sized for the appliance.
Open this job →Fireplace Cleaning
Ash, soot and grime cleared from firebox, doors and hearth so cracks and worn parts can be seen and judged.
Open this job →Gas Fireplace Cleaning
Burner ports, pilot hood, logs, glass and the outside vent cleaned to the steps in your unit's manual.
Open this job →Gas Fireplace Repair
Pilot outages, weak flames, dead remotes and valves that will not open, tested part by part with a meter.
Open this job →Fireplace Remodel
New surrounds, mantels and hearths planned inside the clearance limits first, then finished in the material you pick.
Open this job →Fireplace Inserts
Gas inserts fitted into existing fireboxes with a full-length liner, a new gas line and clearances checked against the manual.
Open this job →Pellet Stove Repair
Error codes read, then the auger, igniter, blowers and safety switches tested one by one until the fault shows.
Open this job →Wood Stove Repair
Door gaskets, baffles, firebrick and combustors replaced with model parts, and wall and floor clearances measured from the label.
Open this job →Gas Logs
Vented log sets sized to the firebox, placed to the maker's diagram, and piped with a shutoff and a leak test.
Open this job →Chimney Seismic Retrofit
Older brick stacks braced, strapped to the framing or rebuilt above the roofline, after a camera look at what is inside.
Open this job →Chimney Crown Repair
Cracked or flat crowns rebuilt with a slope and a lip that sheds rain away from the brick below.
Open this job →Dryer Vent Cleaning
Lint cleared from the dryer duct, wall cap and booster fan, with airflow checked before and after.
Open this job →Chimney Liner Installation
Stainless liners sized to the gas, wood or pellet appliance and run the full height of the flue, with a cap on top.
Open this job →Chimney Leak Repair
Water stains near the chimney traced to the crown, flashing, cap or brick, then fixed where the water gets in.
Open this job →Chimney Waterproofing
A breathable sealer on clean, repaired brick, so rain beads off while moisture inside the masonry can still escape.
Open this job →Chimney Damper Repair
Throat dampers that stick, warp or will not seal repaired or replaced, with top-sealing dampers as an option.
Open this job →