Burrows Chimney Contractors

Wood Stove Repair in Bell, or a Plan for Gas

Describe What You See

On the Burrows Checklist

A wood stove needs a tight door and a safe distance from anything that burns. We test the door and glass gaskets, look over the baffle, firebrick and catalytic combustor, and replace worn pieces with parts made for the model. Then we read the label and measure the gap to walls, ceiling and floor pad. Where a Bell stove has no label, we use the larger NFPA 211 distances and say so.

Door and glass gaskets tested
Baffle and combustor examined
Firebrick replaced to the model
Wall and ceiling gaps measured
Floor pad size checked

The Parts That Wear on a Wood Stove

A wood stove works by controlling air. The door gasket and the glass gasket seal the firebox so air only enters where the stove is designed to let it in. The baffle, a plate or set of bricks across the top of the firebox, holds the gases in the fire long enough to burn. Firebrick protects the steel walls. The stove pipe carries the exhaust to the chimney. Each of these wears with use. A gasket goes flat and hard, and the stove starts burning wood faster than it should and running too hot. A baffle warps or cracks, and the stove smokes and leaves more creosote in the flue. Firebrick cracks and lets heat reach the steel. Glass hazes over from smoky fires and can crack from a log pushed against it. We replace each part with one made for the stove's model, because a gasket or a baffle of the wrong size changes how the whole stove burns.

Clearances matter as much as parts. Every listed wood stove has a label on the back stating how far it must sit from walls and furniture, and what kind of floor protection it needs. A stove that has been moved, a wall that has been paneled, or a rug pulled up close can all put the stove out of line with its label. We measure those distances and the stove pipe's distance to anything that can burn, and look at the pipe joints and the connection into the chimney. On many Bell stoves the pipe has been patched or the joints have come loose. Those go on the repair list. The chimney above gets a look too, and a sweep from $420 often goes with a stove repair, since a stove with a bad gasket leaves a dirty flue.

Repair It, or Move to Gas?

Not every wood stove is worth repairing. A firebox with cracked steel, a stove old enough that parts are not made, or one that does not meet current emission rules can cost more to keep than to replace. In Los Angeles County there is a second question. South Coast AQMD Rule 445 sets no-burn days for wood through the winter, and many owners who use their stove for real heat find those days arrive exactly when they want it most. That is why so many stove owners here ask about gas. A gas stove can sit where the wood stove sat, using a vent run suited to gas. A gas insert can go into a masonry fireplace opening for $2,800 to $5,600 installed. Either way the fire lights from a switch or a remote and there is no wood to buy, store or carry in.

Our written quote lays out both paths when both are on the table. The repair side lists each part by model, the labor, and any clearance fix such as new floor protection or a wall shield. The gas side lists the appliance, the venting, the gas line and the permit steps. Wood-to-gas changes call for a Level 2 inspection, $390, before the new appliance goes in, because a change of fuel is one of the events NFPA 211 names, and the camera shows whether the existing chimney will serve. Homes in Bell, South Gate, Montebello and Los Angeles book a stove visit through the contact form. Send a photo of the stove, the label on its back if you can reach it, and the pipe where it meets the wall or ceiling.

How Burrows Chimney Contractors Handles the Job

Tested First

Readings taken before any part is swapped

Maker's Parts

Listed for the model on your rating plate

Written Price

Agreed before work starts

Your Record

Readings, parts and photos left with you

Jobs That Often Come Next

Chimney Sweep

Soot and creosote brushed out of the flue, with the cap screen, smoke shelf and damper cleared on the same visit.

Open this job →

Chimney Inspection

A Level 1 or Level 2 look at flue, damper, firebox and cap, picked to match what has changed since the last visit.

Open this job →

Chimney Repair

Cracked crowns, open mortar, loose brick and rusted caps repaired after the cause is found, priced line by line in writing.

Open this job →

Fireplace Inspection

Firebox, hearth, mantel gap, damper and any gas parts checked against the building code or the unit's own listing label.

Open this job →

Fireplace Repair

Cracked firebrick, worn refractory panels, stuck dampers and smoky openings repaired with parts and mortars rated for heat.

Open this job →

Chimney Level 2 Inspection

Camera run through the full flue plus attic and crawl space checks, booked for a sale, a new appliance or after a quake.

Open this job →

Chimney Cap Installation

Stainless or copper caps with spark mesh, measured to the flue and fastened so wind cannot lift them off.

Open this job →

Chimney Flashing Repair

Metal at the roofline rebuilt in two overlapping layers, with a cricket behind wide stacks so water runs around them.

Open this job →

Chimney Masonry Repair

Open joints repointed, crumbling brick swapped for matched units and crowns rebuilt, using mortar softer than the brick around it.

Open this job →

Chimney Rebuilds

Loose or leaning stacks taken down to sound brick and built back with steel, ties and a liner sized for the appliance.

Open this job →

Fireplace Cleaning

Ash, soot and grime cleared from firebox, doors and hearth so cracks and worn parts can be seen and judged.

Open this job →

Gas Fireplace Cleaning

Burner ports, pilot hood, logs, glass and the outside vent cleaned to the steps in your unit's manual.

Open this job →

Gas Fireplace Repair

Pilot outages, weak flames, dead remotes and valves that will not open, tested part by part with a meter.

Open this job →

Fireplace Remodel

New surrounds, mantels and hearths planned inside the clearance limits first, then finished in the material you pick.

Open this job →

Fireplace Inserts

Gas inserts fitted into existing fireboxes with a full-length liner, a new gas line and clearances checked against the manual.

Open this job →

Pellet Stove Repair

Error codes read, then the auger, igniter, blowers and safety switches tested one by one until the fault shows.

Open this job →

Gas Logs

Vented log sets sized to the firebox, placed to the maker's diagram, and piped with a shutoff and a leak test.

Open this job →

Chimney Seismic Retrofit

Older brick stacks braced, strapped to the framing or rebuilt above the roofline, after a camera look at what is inside.

Open this job →

Chimney Crown Repair

Cracked or flat crowns rebuilt with a slope and a lip that sheds rain away from the brick below.

Open this job →

Dryer Vent Cleaning

Lint cleared from the dryer duct, wall cap and booster fan, with airflow checked before and after.

Open this job →

Chimney Liner Installation

Stainless liners sized to the gas, wood or pellet appliance and run the full height of the flue, with a cap on top.

Open this job →

Chimney Leak Repair

Water stains near the chimney traced to the crown, flashing, cap or brick, then fixed where the water gets in.

Open this job →

Chimney Waterproofing

A breathable sealer on clean, repaired brick, so rain beads off while moisture inside the masonry can still escape.

Open this job →

Chimney Damper Repair

Throat dampers that stick, warp or will not seal repaired or replaced, with top-sealing dampers as an option.

Open this job →

Chimney Chase Cover

Rusted or dished metal tops on framed chimneys replaced with stainless covers sloped to shed water off the chase.

Open this job →
Call (323) 521-4634